故障现象:压力开关发信号过快
原因分析:
(1)进油口阻尼孔大
(2)隔离膜片碎裂
(3)系统冲击压力太大
(4)电气系统设计有误
解决方法
(1)阻尼孔适当改小,或在控制管路上增设阻尼管
(2)更换隔离膜片
(3)在控制管路上增设阻尼管,以减弱冲击压力
(4)按工艺要求设计电气系统
尺寸图